SATEL INT-KSG 7
4. Triggering the alarm from keypad
If your installer has enabled this feature, the alarms can be triggered from the keypad as
follows:
fire alarm – touch and hold the key for approx. 3 seconds;
medical (auxiliary) alarm – touch and hold the key for approx. 3 seconds;
panic alarm – touch and hold the key for approx. 3 seconds. The installer defines
whether the loud panic alarm (setting off the loud alarm signal) or the silent panic alarm
(without the loud signal) will be triggered.
5. Using selected user functions
All the user functions have been described in the INTEGRA or INTEGRA Plus control panel
user manual. Discussed below are just a few selected functions.
5.1 Changing code
1. Enter the code and confirm using .
2. Touch the 1 key to start the code changing function.
3. Enter the new code and confirm using or .
5.2 Zone bypassing
1. Enter the code and confirm using .
2. Touch the 4 key to display the contents of the Z
ONE BYPASSES
submenu.
3. Depending on whether the zone is to be inhibited or isolated, select the suitable function
(I
NHIBIT
– the zone will remain bypassed until the partition to which it belongs is disarmed,
or until unbypassed by the user; I
SOLATE
– the zone will remain bypassed until
unbypassed by the user) and touch the
or key.
4. The zone list will be displayed graphically, each zone being represented by one of the
following symbols:
– the zone is not bypassed;
– the zone is inhibited;
– the zone is isolated.
Shown at the bottom of the display is the name of the zone currently indicated by the
cursor.
5. Using the arrow keys, move the cursor over the zone to be bypassed / unbypassed.
6. Touch any number key. The previously displayed symbol will be replaced with another
one. Touch the keys three times within 3 seconds: 0 – to display the
symbol for all
available zones, 1 – to display the or
symbol for all available zones (depending on
whether the function enables inhibiting or isolating the zones), and 2 – to invert the
symbols displayed so far.
7. Having selected the zones to be bypassed / unbypassed, touch the or key.
Bypassing the zones lowers the level of protection. Prior to arming, make sure that
there are no accidentally bypassed zones in the partition, which can allow an intruder
to gain access to the protected area, despite the partition is armed.
If a zone is bypassed, call the service immediately to repair the fault.