1 SATELLINE-EASy Pro technical specifications
SATELLINE-EASy Pro complies with the following international standards:
o EN 300 113-2 (RF-requirements)
o EN 301 489 (EMC-requirements)
o EN 60950 (Safety Standard)
o FCC CFR47 part 90
12.5 kHz / 20 kHz / 25 kHz
According to EN 55022 and FCC
CFR47 part 90
100% (@22°C) 20 min
100% (@35 °C) 13 min
40% No limit
100% (@22°C) No limit
100% (@35 °C) 50 min
40% No limit
Frequency Error
Tolerance
-114 dBm @ 12.5 kHz
-111 dBm @ 25 kHz
(BER < 10 E-3)
Adjacent Channel
Selectivity
> 47 dB @12.5 kHz
> 52 dB @ 25 kHz
Intermodulation
Attenuation
120 W typical @ 35 W, min 12 Vdc
100 W typical @ 25W
Power Save Mode
Consumption
SLEEP State:0,4 W typical
10, 20, 25, 35 W / 50 ohm (default)
5, 10, 20, 25W / 50 ohm (Option **)
According to EN 55022 and FCC
CFR47 part 90
*) If high output power is used continuously or with a high cycle, the equipment generates excess heat. The output
power is automatically decreased when necessary to prevent overheating. Typical operating times are shown in the
chart with different output powers and duty cycles @ 22°C and 35 °C (see chapter 3.2).
**) Limited output power is available as on order option
Note 1
Due to radio electronic design, the receiver is about 6 – 15 dB less sensitive on the following frequencies:
403.000, 416.000, 429.000, 442.000, 455.000, 468.000, 409.5875 and 469.200 MHz.