12.1.2 Fuse
A proper fuse must be connected in between the radio modem and the power supply. The correct
value is 15A for SATELLINE-EASy Pro.
12.1.3 Power supply
The allowed operating voltage is +9 ... +16 V
DC
. The radio modem must only be connected to a
power supply with an adequate current output (power rating minimum is 120W). The pins 1 and
2 of the 4pin Odu-connector are connected to the positive power supply line. The pins 3 and 4
are connected to negative power supply line (ground).