SATEL SMET-256 17
The IP address and port defined in the "Program settings" tab may be different from
the IP address of the converter programmed in the "Network" tab and the port
programmed in the "Login details". This will depend on whether the communication
will be established within the same local network, or within a public network.
Appearance and style
Parameters defined in this area are used for programming the appearance of windows
displayed in the SMET-256 Soft program. There are two graphic styles available in the
program, i.e. "BusinessBlackSteel" and "Windows". For the changes to take effect,
select the appropriate field, click on the "Apply" button and restart the program.
Fig. 11. "Program settings" tab, "Configuration" window in the SMET-256 Soft program (the
window is not available in the web browser).
5. SPECIFICATIONS
Power supply ................................................................................................ 12 V DC / 750 mA
Working temperature range (Class I):..................................................................... +5…+40 °C
Enclosure dimensions...................................................................................125x114.5x31 mm
Weight incl. accessories ................................................................................................... 300 g
The latest EC declaration of conformity and certificates are available for
downloading on our website www.satel.pl