20 INTEGRA 128-WRL SATEL
EOL (end of line resistor),
2EOL/NC (double end of line resistor, NC type detector),
2EOL/NO (double end of line resistor, NO type detector).
The value of resistors used in EOL and 2EOL configurations is programmable within the
range from 500 Ω to 15 kΩ for zones:
on the control panel mainboard – the value of R1 and R2 resistors is programmed
individually for the 2EOL configuration (see Fig. 17). The resistor value for EOL
configuration is a sum of values programmed as R1 and R2.
in the zone expanders identified by the control panel as CA-64 Ei and CA-64 EPSi.
Depending on the expander program version, configure the following:
version 4.00 – the value of R1 and R2 resistors for 2EOL configuration (see Fig. 17).
The resistor value for EOL configuration is a sum of values programmed as R1 and R2.
version 2.00 or 2.01 – the resistor value for EOL configuration. For the 2EOL
configuration, a single resistor value equals to half the defined quantity.
In order to make the circuit in the zones of LCD keypads and other expanders (CA-64 ADR,
INT-IORS, CA-64 PP) in EOL configuration, use 2.2 kΩ resistor, and in 2EOL configuration
- 1.1 kΩ resistors.
The zones on the mainboard and in zone expanders identified by the control panel as
CA-64 Ei and CA-64 EPSi can additionally work in the following configurations:
roller (dedicated for connecting roller shutter motion detector),
vibration (normally closed, dedicated for connecting vibration detector – an NC type of
detector, e.g. magnetic contact, may be connected in series with the vibration detector).
All zones in the system can be made dependent on the output status. Activating the output
amounts to violation of the zone (the output and the zone does not need to be physically
connected). The zone does not need to exist physically, because virtual zones may be used
as well. In case of the physically existing zones, programmed as the "follow output" ones, the
physical violations and tampers of the zone are disregarded.
INTEGRA 128-WRL
NC TMP COM
12V
NC TMP
NC
Fig. 14. Exemplary connection of NC type detector to control panel (NO type detector should
be connected in the same way).
The AUX power supply output or any of the high-current outputs (OUT1 or OUT2),
programmed as POWER SUPPLY OUTPUT, can be used for powering detectors. In case of
extended systems and large distances to the control panel, the detectors may be powered
from expanders fitted with power supply units, or from additional power supply units.